Good morning from Spain,
I would like to know your opinion about a rework process requested by one
of our PCB suppliers once we rejected a lot of rigid multilayer gold plated
boards due to a non wetting problem. Boards are for class 3 applications
and they are bonded with adhesive to a metal plate (heat sink)
Solder paste didn’t wet the pads. Boards had a dark gold color, as if some
stuff was covered the board surface.
Our supplier has proposed the following method:
1/ Clean the boards @ 50ºC during 3 minutes with a solution of: degreasing
(5%)+ sulfuric acid (10%)+ deionized water (85%)
2/ Rinsing (water)
3/ Drying (air pressed + heat cabinet)
Our concern is if acid could be trapped into the vias (the board is bonded
to a metal plate) or if we could have any kind of problem in the future.
Thank you for your comments,
Juan T. Marugán López
Indra
Production Quality
Defense Electronic Equipment
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------
|
|
|