        Some extracts of the article pointed out by Steve are below. Thicker
is better as far as joint fatigue, which makes sense. Copper is not as
flexible as solder.
        Ramon
> Information on how the ramp time, hold time, frequency, and temperature
> affect the fatigue life of solder joints has been studied and published
> [Vayman]. However, information on how the height of the solder joints
> affects the fatigue life of surface mount solder joints is not readily
> available.
> This solder joint fatigue problem presented an interesting question.
> Should the solder joints be reworked to increase solder joint thickness
> and lengthen the fatigue life? Several engineers had conflicting points of
> view on how the height of the solder would affect the fatigue life.
> The NASA hand soldering requirements in NHB5300.4 (3A-2) indicate that,
> for lapped solder joints, the maximum distance between the foot of the
> lead and the termination is .010 inch.
> Solving for Stress and Strain Values. The finite element analysis code,
> ABAQUS, was used to solve the mathematical model of the SOT23 package. The
> results of the analysis are depicted in Table 1 and Figure 2. FEA showed
> that increasing the thickness of the solder joint did not affect the
> overall stress values on the SOT23 package as a whole. However, it did
> show that the strain values on the solder joint were affected by changing
> the thickness of the solder.
> FEA showed that increasing the solder joint height may have a favorable
> effect on the solder joint's fatigue life. As a direct result of
> increasing the thickness of the solder joint, the plastic strain in the
> solder was reduced. The fatigue life of the solder joint doubled from 28.5
> cycles at 2 mils to 59.2 at 10 mils. Our results show that below 4 mils,
> the solder joint was subject to cyclic failure much sooner. After 4 mils,
> the number of cycles increased with thickness, but not as drastically as
> it did from 2 to 4 mils. This is evident in Figure 3.
>
>
> -----Original Message-----
> From: Steve Gregory [SMTP:[log in to unmask]]
> Sent: Wednesday, October 01, 2003 4:56 PM
> To:   [log in to unmask]
> Subject:      Re: [TN] Reliability solder
>
> Hi Paul!
>
> To answer your question; Is water wet? Does a bear poop in the woods?
> (GRIN)
>
> After careful consideration, one would have to answer in the affirmative
> to both scenarios posed above. So the short answer to your query is;
> "uh-huh"...go to:
>
> http://nepp.nasa.gov/eeelinks/vol_01/no_02/eee1-2d.html
>
> Here you will find a summary of a report done by Hyun Soo Park of NASA,
> "Theoretical Analysis to Determine how Solder Joint Height Affects the
> Fatigue Life of the Solder Joint". It also has a list of references that
> include no other than our own Technetter guru; Werner Engelmaier, of all
> the work that's been done in this area.
>
> -Steve Gregory-
>
>
>
>
>
>
>
>
>
>
>       Paul Stolar
>       Materials Engineer
>       Houston Technology Center
>       Baker Atlas
>       713-625-5376
>       713-625-4949 (fax)
>
>
>
>
>
>       Has anyone ever done any experiments to determine the effect the
> solder
>       thickness under a lead has on the joint's reliability?
>
>       Paul Stolar
>       Materials Engineer
>       Houston Technology Center
>       Baker Atlas
>       713-625-5376
>       713-625-4949 (fax)
>
>
>
>
> ---------------------------------------------------
> Technet Mail List provided as a free service by IPC using LISTSERV 1.8e
> To unsubscribe, send a message to [log in to unmask] with following text in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt or (re-start) delivery of Technet send e-mail to
> [log in to unmask]: SET Technet NOMAIL or (MAIL)
> To receive ONE mailing per day of all the posts: send e-mail to
> [log in to unmask]: SET Technet Digest
> Search the archives of previous posts at: http://listserv.ipc.org/archives
> Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
> for additional information, or contact Keach Sasamori at [log in to unmask] or
> 847-509-9700 ext.5315
> -----------------------------------------------------
>

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------

ATOM RSS1 RSS2