        Wayne:
        Do you think that filling the vias with solder or with a lead and
solder will give the via more stability and keep it from tearing out?
        Just a thought.
        Ramon

> -----Original Message-----
> From: Wayne Pritchett [SMTP:[log in to unmask]]
> Sent: Monday, September 29, 2003 8:09 AM
> To:   [log in to unmask]
> Subject:      Re: [TN] Selective Edge Plating
>
> I succeeded with an adapter board like the one you describe. I placed a
> row of vias down each edge of the board, then we routed the board outline
> right down the middle of the vias.
>
> We did get some tearout of the vias, so I suggest that you leave a little
> more than half of the via when you trim the edges. Maybe put some pads on
> inner layers to anchor the vias better. Be sure and use a mild flux.
>
> Wayne Pritchett
>
> ---------------------------------------------------
> Technet Mail List provided as a free service by IPC using LISTSERV 1.8e
> To unsubscribe, send a message to [log in to unmask] with following text in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt or (re-start) delivery of Technet send e-mail to
> [log in to unmask]: SET Technet NOMAIL or (MAIL)
> To receive ONE mailing per day of all the posts: send e-mail to
> [log in to unmask]: SET Technet Digest
> Search the archives of previous posts at: http://listserv.ipc.org/archives
> Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
> for additional information, or contact Keach Sasamori at [log in to unmask] or
> 847-509-9700 ext.5315
> -----------------------------------------------------
> 203-924-3170

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------

ATOM RSS1 RSS2