Hi gang! Steve - one more addition to Ryan's list: the Hi-temp solderballs
eliminate some of the "tolerance" benefits that a eutectic solderball gives
you in terms of placement, collapse, and self alignment.
Dave Hillman
Rockwell Collins
ddhillma@rockwellcollins
Ryan Grant
<[log in to unmask] To: [log in to unmask]
M> cc:
Sent by: TechNet Subject: Re: [TN] 5Sn / 95Pb Solder Sphere
<[log in to unmask]>
09/24/2003 06:03
PM
Please respond to
"TechNet E-Mail
Forum."; Please
respond to rgrant
Hi Steve,
OEMs don't put Hi-temp balls on the corners because intermixing alloys it
is not conducive to mass production. Or at least not without a lot of pain
in package manufacturing.
Ryan Grant
-----Original Message-----
From: Steve Gregory [mailto:[log in to unmask]]
Sent: Wednesday, September 24, 2003 4:27 PM
To: [log in to unmask]
Subject: Re: [TN] 5Sn / 95Pb Solder Sphere
Hi Jim!
Sounds like you have the problem of excessive ball collapse with BGA's
solved! I wonder why the OEM's haven't done something like this? It's not
like this is an obscure problem...
Silly question; is it possible to replace only the corner balls with
Hi-temp balls? See? I told you it was a silly question...
-Steve Gregory-
It just so happens that we build a multi-chip module using a 625-BGA
package. We buy the empty package from Kyocera, install multiple die and
discretes, seal the lid, attach the balls (4 hi-temp in the corners) and
solder the BGA to our PWB.
Jim Marsico
Senior Engineer
Production Engineering
EDO Electronics Systems Group
[log in to unmask] <mailto:[log in to unmask]>
631-595-5879
-----Original Message-----
From: Steve Gregory [SMTP:[log in to unmask]]
Sent: Wednesday, September 24, 2003 3:25 PM
To: [log in to unmask]
Subject: Re: [TN] 5Sn / 95Pb Solder Sphere
Jim,
Do you get the devices like that, or do you put the hi-temp balls in
the corners yourself?
Thanks!
-Steve Gregory-
Victor, we use high temp solder balls on the 4 corners of a
625 ceramic BGA.
The main purpose is to prevent the device from collapsing,
causing solder
bridging. Maintaining the stand-off height after reflow
also increases long
term reliability.
Jim Marsico
Senior Engineer
Production Engineering
EDO Electronics Systems Group
[log in to unmask] <mailto:[log in to unmask]>
631-595-5879
---------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-509-9700 ext.5315
-----------------------------------------------------
---------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-509-9700 ext.5315
-----------------------------------------------------
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------
|