Graham,
I don't know if you are automatically or manually spraying.  For automatic
spraying, we've installed precision flowmeters.  The volume dispensed data
is compared to tolerance limits set in the programmable controller by the
spray routine.  The machine alarms if the assembly is coated out of
tolerance and corrective action can be taken immediately by the operator -
before the material is cured.  We also capture the data in our quality
management database for trend analysis purposes.

Steve



-----Original Message-----
From: Collins Graham [mailto:[log in to unmask]]
Sent: Tuesday, September 16, 2003 2:02 PM
To: [log in to unmask]
Subject: [TN] measuring the thickness of cured conformal coating


Hello TechNet!
I've got a question for the conformal coaters out there.

Our situation:  We currently measure CCA thickness before application,
and then again after application & cure of conformal coating, to
determine how thick a coating we have applied.  We are currently using a
micrometer to measure the thickness.  Our coating thickness is in the
0.001" to 0.005" range.

My question is: what are others using to do this sort of measurement?
Are there are better tools out there to do this faster / better?

Thanks!

regards,

Graham Collins
Process Engineer,
Northrop Grumman Canada Corporation
Halifax
(902) 873-2000 ext 6215

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-509-9700 ext.5315
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------

ATOM RSS1 RSS2