TECHNET Archives

July 2003

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
"Jason W. Gregory" <[log in to unmask]>
Reply To:
TechNet E-Mail Forum.
Date:
Tue, 8 Jul 2003 14:33:54 -0500
Content-Type:
text/plain
Parts/Attachments:
text/plain (132 lines)
Chris,

Are you saying that if I double reflow a standard FR4 board, then I'm
jeopardizing reliability? My whole career, I've used standard FR4 (140-170
Tg) at temps of roughly 220-230 each pass. Please elaborate.



Jason Gregory
SMT Production Supervisor/
Integrated Product Team Leader
LaBarge Inc.
(918)459-2367
(918)459-2221 fax
[log in to unmask]
http://www.labarge.com


                                                                                                                                          
                      Chris Robertson                                                                                                     
                      <chris.robertson@GET        To:       [log in to unmask]                                                      
                      S-1000.COM>                 cc:                                                                                     
                      Sent by: TechNet            Subject:  Re: [TN] Operating temperature of PCB                                         
                      <[log in to unmask]                                                                                                
                      c.org>                                                                                                              
                                                                                                                                          
                                                                                                                                          
                      07/08/2003 02:09 PM                                                                                                 
                      Please respond to                                                                                                   
                      Chris Robertson                                                                                                     
                                                                                                                                          
                                                                                                                                          




This is a topic I've addressed in my book. The temperature rating
is really cumulative. I can't give a direct approximation because of the
difference between the way assembly houses assemble boards, but
the Tg really applies for board assembly. The Tg should be more than
the temperature of the solder flow...cumulatively. Every pass
diminishes the board.
for an example, if your board has a (unrealistic) Tg of 150F and the
bath was 100F, the material would be suitable, but it the board
must go through 2 passes for assembly you are in trouble.
Double sided assembly is similar. An assembly house will take 2 passes
of the board through the solder flow.
I haven't seen a table or chart showing the amount of degradation in the
material for each pass. Therefore we must use common sense methods
and determine first the number of passes required for assembly, (getting
a quote on assembly before specifying the material) and then determine
the material.
I think most use experience and "hard lessons" to determine these values.

Chris Robertson
Author "PCB Designer's Reference"
[log in to unmask]

 ----- Original Message -----
 From: Robert Tarzwell
 To: [log in to unmask]
 Sent: Tuesday, July 08, 2003 12:48 PM
 Subject: Re: [TN] Operating temperature of PCB

 Hi Michel

 even though most people feel that as long as the temp is below the T/g
 then
 everything is fine in PCB land, however some long term studies I did
 showed
 that in fact everything is not fine in PCB land. When you run a FR4 pcb
 hotter a couple of problems arise, first the hotter you get it the more it
 starts to carbonize, the longer you keep it at a high temp the worse
 things
 get. one study showed with as little as three months at 100 deg C lowers
 the
 dialectric voltage rating as much as 30 percent. the temp your talking
 about
 is right on the border line for FR4,even high temp stuff a switch to BT
 epoxy or polyimide may be in order , polyimide is 2 to 3 times the price
 but
 BT epoxy gives you a higher operationg temp with only 1.2 X the cost. The
 damage to the base lam is based on time at temp and max temp the hotter
 and
 the longer the more damage is done, I have seen even 80 deg c type temp
 turn
 a fr4 board brown over the years. I have advocated for years that 160 deg
 FR4 has a max long term operating temp of 100 deg C.  i would suggest you
 talk with some of the laminate tech guys  ( not sales type) and see what
 they say.
 robert tarzwell   megadawn.com

 ---------------------------------------------------
 Technet Mail List provided as a free service by IPC using LISTSERV 1.8e
 To unsubscribe, send a message to [log in to unmask] with following text in
 the BODY (NOT the subject field): SIGNOFF Technet
 To temporarily halt or (re-start) delivery of Technet send e-mail to
 [log in to unmask]: SET Technet NOMAIL or (MAIL)
 To receive ONE mailing per day of all the posts: send e-mail to
 [log in to unmask]: SET Technet Digest
 Search the archives of previous posts at: http://listserv.ipc.org/archives
 Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
 information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700
 ext.5315
 -----------------------------------------------------
---------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700
ext.5315
-----------------------------------------------------



---------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------

ATOM RSS1 RSS2