Howard

When switching over to T/R for Moisture Sensitive Parts (particularily
Level 4+) you need to keep in mind your usage QTY's.  If small volumes are
being used then T/R may not be the way to go (regardless of what the buyers
say).  The cost savings could easily be lost by the time/labour used to
bake/reseal leftover parts.

J-STD-033A states that after 1hr exposure, left over parts will need to be
resealed or baked to stop further moisture migration and to reset the floor
life clock. Look at section 4.1.xx of the J-STD (reseal times with fresh
dessicant is 5x's the exposure time(12hr max) for level 2-4 and 10X the
exposure (8hr max)for level 5-5A) or bake .

Andre Leclair
Process Engineer
Ansen Corp.

---------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------

ATOM RSS1 RSS2