As a correction, Parylene is not a self limiting process and will continue
to deposit material until the Dimer source is exhausted or the process time
ends. Thickness is controlled by process time and Dimer volume. A typical
thickness is 1 mil +/- 1/2mil and is effective against salt fog.
Regards,
Bruce Misner
-----Original Message-----
From: Dominique Lutrat [mailto:[log in to unmask]]
Sent: Tuesday, July 08, 2003 1:55 AM
To: [log in to unmask]
Subject: [TN] RE : [TN] Salt fog testing and paralyne
As far as I am aware the Paralene process is self limiting and stops at a
monolayer of molecules.
SCS would tell you exactly what goes on.
-----Message d'origine-----
De : TechNet [mailto:[log in to unmask]] De la part de Suzanne Nachbor
Envoyé : lundi 7 juillet 2003 21:15
À : [log in to unmask]
Objet : [TN] Salt fog testing and paralyne
Does anyone have literature or real life testing on the performance of
paralyne under a salt fog test? What thickness was required to pass salt
fog testing? Was the cca directly exposed or was it inside a box/device?
Suzanne Nachbor
Supplier Quality Engineer/Commodity Lead
Phone: 763-957-3923
Fax: 763-792-2486
e-mail: [log in to unmask]
---------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8e To
unsubscribe, send a message to [log in to unmask] with following text in the
BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
(re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet
NOMAIL or (MAIL) To receive ONE mailing per day of all the posts: send
e-mail to [log in to unmask]: SET Technet Digest Search the archives of
previous posts at: http://listserv.ipc.org/archives Please visit IPC web
site http://www.ipc.org/html/forum.htm for additional information, or
contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------
---------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700
ext.5315
-----------------------------------------------------
---------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------
|
|
|