Hi Ofer,
'Tis a pity you do not have a lab; however...., I take it you have a desk and
a screwdriver [not too large] and..... I take it you can sacrifice every so
often one of the components so cheaply acquired by your purchasing department
[who runs your company anyway?] together with one of your, I am sure also
cheaply procured, circuit boards, run an assembly test, and pry off [use your
'calibrated' hands with the not-too-large 'calibrated' screwdriver]. The force this
takes is immaterial, what is important is the resulting failure mode(s). If
the separation is interfacial cleanly between the soldering pads and the solder
balls =>REJECT, if the soldering pads a ripped of the PCB [or the compentent]
=>ACCEPT.
Regards,
Werner Engelmaier
Engelmaier Associates, L.C.
Electronic Packaging, Interconnection and Reliability Consulting
7 Jasmine Run
Ormond Beach, FL 32174 USA
Phone: 386-437-8747, Fax: 386-437-8737, Cell: 386-316-5904
E-mail: [log in to unmask], Website: www.engelmaier.com
---------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------
|
|
|