any flux you use to solder assemblies (smt and plated thru hole) which may
be nicknamed: no clean, water soluble, RMA, washable, removable, etc. should
be better understood by you through testing.  this can include ion
chromatography testing (to detect surface chlorides, bromides, other halides
as well as weak organic acid) in addition to surface insulation testing SIR,
to further understand what type and amount of contaminant is present.  these
could present a risk of electromigration, based on the test results.

then, after that, you can see if there's any correlation between these tests
and the ionograph. Many no cleans show poor correlation to traditional gross
extract tests like the ionograph, since the residues stick to the joint
better than a water-soluble flux residue, for example.

  depending on the flux type, manufacturer, process, PWB finish, etc, you
may be able to "Know" whether your board assembly is "clean"

Michael Weekes
Master Engineer - EOE
Hamilton Sundstrand / UTC
MS 190-6
4747 Harrison Ave. PO Box 7002
Rockford, IL 61125-7002
815 394 3362
[log in to unmask]


-----Original Message-----
From: Poh Kong Hui [mailto:[log in to unmask]]
Sent: Monday, May 05, 2003 11:01 AM
To: [log in to unmask]
Subject: Re: [TN] : Ionic contamination limit level for Ionograph


Hi Again,

As far as I understand ionic contamination level check is more of cleaning
process. Can it be used for no-clean, and what if the measured level is
more than 10 ug per sq. inch. ?

Somesone help to advise.

Thanks.

Poh




At 03:13 PM 5/1/03 -0500, Chris Almeras wrote:
>We use 10 ug per sq inch unless otherwise specified by the customer. I
believe the 10ug is per J-std.
>
>Chris Almeras
>
>-----Original Message-----
>From: Poh Kong Hui [mailto:[log in to unmask]]
>Sent: Thursday, May 01, 2003 11:21 AM
>To: [log in to unmask]
>Subject: [TN] : Ionic contamination limit level for Ionograph
>
>
>Hi All,
>
>I would like to know what is the limit level for board cleanliness, if
>using  Ionograph.
>I remember the limit level for using Omegameter is 14, but can't remember
>what unit.
>
>Please enlighten me.
>
>Thanks.
>
>Poh
>
>---------------------------------------------------
>Technet Mail List provided as a free service by IPC using LISTSERV 1.8e
>To unsubscribe, send a message to [log in to unmask] with following text in
>the BODY (NOT the subject field): SIGNOFF Technet
>To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
>To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
>Search the archives of previous posts at: http://listserv.ipc.org/archives
>Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
>information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700
ext.5315
>-----------------------------------------------------
>

---------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700
ext.5315
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest