Same questions I asked month ago (04-27-2003) relating to spare parts /
populated PCBS.
I didn't find any std.
Sensitive components: Active components, Elect. caps, crystals, solder
joints, fine pitch packages.
Recommended packages: positive pressure of dry Nitrogen, Vacuum dry package
with desiccant.
Every 1 -3 years its recommended to operate / Inspect it and repack.
Best Regards
ROKAH Reuven
Chief Engineer
ECI Telecom LTD.
Operations Division
30 Hasivim St. Petah-Tikva 49517
ISRAEL
Tel: 972-3-9266734 Mobile:972-55-786734
Fax: 972-3-9266480
e mail: [log in to unmask]
"Zweigart,
Siegmund" To: [log in to unmask]
<SiegmundZweigart@ cc:
HG.SLR.COM> Subject: [TN] Storage - Shelflife of populated PCBA's
Sent by: TechNet
<[log in to unmask]
IPC.ORG>
26/05/03 07:29 PM
Please respond to
"TechNet E-Mail
Forum."; Please
respond to
"Zweigart,
Siegmund"
Hello all
What is important for the storage of populated PCBA's?
Are electrolytic caps the only critical parts?
How often have they to be loaded?
Are there any standards dealing with this topic (storage of populated
PCBA)?
Which are the critical components?
best regards
Siggi
---------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700
ext.5315
-----------------------------------------------------
---------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------
|
|
|