Edward:

Nobody adds aqueous ammonia, it adds too much water to the etchant.  What you
are proposing, controlling pH by addition of ammonia, is a very good idea,
and often done by sparging in anhydrous ammonia.  The key is to use a sparger
(to create tiny bubbles of ammonia) and to do it slowly, and only when the
pumps are on.

The conversion of ammonia gas to ammonium hydroxide is essentially
instantaneous, but you still do it slowly, to make sure the ammonia bubbles
do not rise to the surface before they are absorbed.

Good luck

Rudy Sedlak
RD Chemical Company

---------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------

ATOM RSS1 RSS2