Hi Roland,
You assume incorrectly that IPC-TM-650, TM 2.4.3.2 is only for copper-clad
flexible dielectrics; its title is: "Flexural Fatigue and Ductility, Flexible
Metal-Clad Dielectrics," and the TM is applicable for any flexible metal
cladding. I know, because I developed the TM and have applied it to different
metals, however not to Immersion Tin, Immersion Silver or ENiG.
Werner Engelmaier
Engelmaier Associates, L.C.
Electronic Packaging, Interconnection and Reliability Consulting
7 Jasmine Run
Ormond Beach, FL 32174 USA
Phone: 386-437-8747, Fax: 386-437-8737, Cell: 386-316-5904
E-mail: [log in to unmask], Website: www.engelmaier.com
---------------------------------------------------