In our case I have been told that the netlist testing is only done on one out of the lot.
Charles
-----Original Message-----
From: Fineline Circuits, Inc. [mailto:[log in to unmask]]
Sent: Monday, May 19, 2003 4:26 PM
To: [log in to unmask]
Subject: Re: [TN] PCB_OPEN_VIAS_PROBLEMS
Wesley:
Weren't these boards tested by your board supplier? Electrical testing
should have failed the boards with the open vias . The vias may have voids
due to bad drilling and deburring which may clog the hole, poor smear
removal or malfunction of the electroless copper line-trapped air or could
be plating voids. Cross section of the open vias should pinpoint the
problem.
Sona
Fineline Circuits Inc.
---------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------
---------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------
|
|
|