Bev,
I don't recall seeing any statements verbatim to what you've described below
but see section 6.3.1 (Fig. 6-6) of A610 Rev. C and section 9.2.5.1 of
J-STD-001C. These sections do talk about allowable solder depression (up
to a maximum of 25%). But I would also recommend finding out what type of
environment the assembly will end up in. High vibratory and/or thermal
shock environments may need further review before stating that such solder
depression is okay. Hope this helps.
Rich Lasko
Badger Electronics
-----Original Message-----
From: Bev Christian [mailto:[log in to unmask]]
Sent: Friday, May 30, 2003 3:49 PM
To: [log in to unmask]
Subject: [TN] PTH Hole Fill
Technetters,
Someone in our company is quite sure "there was a relaxation of solder fill
when and if the lead of the component was not sufficiently large enough
compared to the PTH to which it was soldered". I have no recollection of
such a change in A610. But the maybe some of my brain cells are on vacation.
Can anyone comment on the statement about hole fill, please? Thanks.
Bev Christian
Research in Motion
---------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700
ext.5315
-----------------------------------------------------
---------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------
|
|
|