Conduction reflow would help.  In theory, you have few degree difference
between the fully formed solder joint (old joint) and fine solder sphere
paste for reflow.  The paste would reflow a bit lower temperature.  As
long as all the surface tension still hold for the old joint, you should
be OK, unless the components is in the "cavity down" and weight a bit
too much = can't hold by surface tension..... ;-(.

jk

>-----Original Message-----
>From: TechNet [mailto:[log in to unmask]] On Behalf Of Rick Thompson
>Sent: Thursday, April 24, 2003 12:46 PM
>To: [log in to unmask]
>Subject: [TN] 'Unique' BGA Reflow Problem
>
>
>We have a customer who had a custom BGA built with some
>additional components besides the die under the encapsulant.
>Unfortunately, these parts were soldered with Sn63Pb37 and the
>solder reflows and bridges under the encapsulant during
>reflow.  Due to time constraints they would like to find a way
>to use these while they wait for new parts to be fabbed.
>We've tried various types of shielding, but the convection
>systems we have heat the entire part causing the internal
>reflow.  Does anyone know of a focused reflow system that
>would allow reflowing the eutectic balls of a BGA but not
>apply enough heat to the top of the component to reflow the
>other parts?  Would one of the focused IR systems (Ersa, PDR)
>do this?  Other possibilities?
>
>Thanks in advance.
>
>Rick Thompson
>
>Sr. SMT Process Engineer
>SMTEK International, Inc.
>+1 (805) 532-2800
>[log in to unmask]
>
>---------------------------------------------------
>Technet Mail List provided as a free service by IPC using
>LISTSERV 1.8e To unsubscribe, send a message to
>[log in to unmask] with following text in the BODY (NOT the
>subject field): SIGNOFF Technet To temporarily halt or
>(re-start) delivery of Technet send e-mail to
>[log in to unmask]: SET Technet NOMAIL or (MAIL) To receive ONE
>mailing per day of all the posts: send e-mail to
>[log in to unmask]: SET Technet Digest Search the archives of
>previous posts at: http://listserv.ipc.org/archives Please
>visit IPC web site http://www.ipc.org/html/forum.htm for
>additional information, or contact Keach Sasamori at
>[log in to unmask] or 847-509-9700 ext.5315
>-----------------------------------------------------
>

---------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------

ATOM RSS1 RSS2