Hi,
I would be wary too. I believe IPC states 25mils end to end, and 40mils
side to side. You could go closer, but, for improved yields this rule works
great.
Regards,
Brent
-----Original Message-----
From: Phil Rothbauer [mailto:[log in to unmask]]
Sent: Wednesday, April 16, 2003 11:02 AM
To: [log in to unmask]
Subject: [TN] Minimum component spacing
To All,
I have some 0805 resistors placed on a board, the supplier says its no
problem laying them out with no space between components. I was wondering
is there a specification for SMD minimum spacing. Because I am vary wary
of this claim for many reasons.
******************************************
Phil Rothbauer
Test Development Engineer
Delphi Delco Electronic Systems
1912 Trialon Ct M/S 1500
Kokomo, IN 46901
765.451.5009
*******************************************
[log in to unmask]
*******************************************
---------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700
ext.5315
-----------------------------------------------------
---------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------
|
|
|