Dale,
I believe you will find the IPC 7711/7721 Rework/Repair and Modifications
manual helpful. The procedure for lifted pad repair using the film adhesive,
according to 7721 manual (don't recall the section #) has the highest level
of conformance.
I attended the instructor certification at Soldering Technology International
recently and now see ways to cut costs tremendously by repairing instead of
scrapping. You might want to consider sending someone for the operator
proficiency, if not the instructor certification training.

---------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------

ATOM RSS1 RSS2