Thanks, Guy, BUT this has to do with cleaning rather than mechanical reliability. 
Bev
--------------------------
Sent from my BlackBerry Wireless Handheld (www.BlackBerry.net)


-----Original Message-----
From: Guy Ramsey <[log in to unmask]>
To: 'TechNet E-Mail Forum.' <[log in to unmask]>; Bev Christian <[log in to unmask]>
Sent: Thu Mar 20 13:17:55 2003
Subject: RE: [TN] SMT Component Standoffs

 
There is help in IPC-SM-782A section 3.6.1.7 Component Stand Off Height
for Cleaning and the associated table 3-7. The stand off recommendation
varies with the component size. For example small component < 3mm x 3mm
stand off > 0.05 mm.
A large component 50mm x 50 mm stand off > 0.5 mm. 

> -----Original Message-----
> From: TechNet [mailto:[log in to unmask]] On Behalf Of Bev Christian
> Sent: Thursday, March 20, 2003 12:56 PM
> To: [log in to unmask]
> Subject: [TN] SMT Component Standoffs
> 
> 
> TechNetters,
> When I was at a former employer there was a minimum stand off 
> in the company specs.  I have forgotten what that was.  Now I 
> know that it can/should be different based on the solder, use 
> environment, pad sizes and lead/termination materials, but I 
> was wondering if anyone would be willing to share what they 
> have on the subject. I am particularly interested in land 
> grid array devices, if I may be so bold as to be picky.  :)   
> Thanks in advance.
> Bev Christian
> Research in Motion
> 
> ---------------------------------------------------
> Technet Mail List provided as a free service by IPC using 
> LISTSERV 1.8e To unsubscribe, send a message to 
> [log in to unmask] with following text in the BODY (NOT the 
> subject field): SIGNOFF Technet To temporarily halt or 
> (re-start) delivery of Technet send e-mail to 
> [log in to unmask]: SET Technet NOMAIL or (MAIL) To receive ONE 
> mailing per day of all the posts: send e-mail to 
> [log in to unmask]: SET Technet Digest Search the archives of 
> previous posts at: http://listserv.ipc.org/archives Please 
> visit IPC web site http://www.ipc.org/html/forum.htm for 
> additional information, or contact Keach Sasamori at 
> [log in to unmask] or 847-509-9700 ext.5315
> -----------------------------------------------------
> 

---------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------

ATOM RSS1 RSS2