Charlie: I don't believe the 1997 GR-78-Core doc calls out an equivalence or
"f" factor to multiply by. It does call out the test procedure which
includes running the test until there is no change in the ionic extraction
value for 5 minutes.

With the Omega 600 you should only have to put in the board surface area and
extraction volume and it will calculate the ug/sq.. in of NaCl equivalent
for you.

Another thought 633.5 sq.. in of surface area is a pretty large board,
unless they are spotting you a heck of a lot of area for the components. The
standard tank will hold a 12X16 board, unless you have the special extra
large extraction tank on your Omega meter it might not totally fit.



Regards

Michael Barmuta

Staff Engineer

Fluke Corp.

Everett WA

425-446-6076


 -----Original Message-----
From: Charlie Pitarys [mailto:[log in to unmask]]
Sent: Thursday, February 27, 2003 8:17 AM
To: [log in to unmask]
Subject: [TN] Ionic Equivalence



I need to meet a Bellcore requirement on an assembly of 6.45ugrams/sq.in.
(Based on the pwb surface area)

The assembly has 633.5 sq.in. surface area.

The customer has supplied me with documentation from;
Physical Design and Manufacture of Telecommunications Products PWB Assembly
Requirements,  GR-78-CORE, Issue 1, Sept 1997. Section 7.1.3.9

I have an Omegameter 600. Is there an equivalence factor, etc? Or is it a 1
to 1 deal?

Thanks in advance.

Charlie
---------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700
ext.5315
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------

ATOM RSS1 RSS2