Look in MIL-PRF-38534 or MIL-STD-883.
The glass frit seal should not be chipped or broken. I will try to look up
the specific sections for you today some time.
You can re-qual the parts by submitting them to a "bomb" test; place the
parts in a high pressure vessel evacuate the vessel then pressurize with a
nitrogen helium mix for ??? hrs. follow this with a fine and gross leak
test. Even if the parts pass this test I would worry about the long term
integrity of the hermetic seal. This may or may not be a concern in your
application.
Dan

---------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------

ATOM RSS1 RSS2