Hi Charlie,
I had a question about this at the end of September last year and
received many answers (search for the thread "Ionograph measurements").
For the Omegameter 600 the equivalence factor is 1.39.
I will send you some relevant documentation off-Technet, as attachments
are stripped by the Technet-server.
Daan Terstegge
Thales Communications
Unclassified mail
Personal Website: http://www.smtinfo.net
>>> [log in to unmask] 02/27/03 05:16pm >>>
I need to meet a Bellcore requirement on an assembly of
6.45ugrams/sq.in.
(Based on the pwb surface area)
The assembly has 633.5 sq.in. surface area.
The customer has supplied me with documentation from;
Physical Design and Manufacture of Telecommunications Products PWB
Assembly
Requirements, GR-78-CORE, Issue 1, Sept 1997. Section 7.1.3.9
I have an Omegameter 600. Is there an equivalence factor, etc? Or is it
a 1
to 1 deal?
Thanks in advance.
Charlie
---------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV
1.8e
To unsubscribe, send a message to [log in to unmask] with following text
in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/html/forum.htm for
additional
information, or contact Keach Sasamori at [log in to unmask] or
847-509-9700 ext.5315
-----------------------------------------------------
---------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------
|
|
|