FYI - If anyone needs field service or support for their Photondynamics
machines (or CRTech or IRSI), former Photondynamics employees have started
their own company.

See www.aoi-services.com and www.aoisupport.com

-----Original Message-----
From:   Larry Koens [SMTP:[log in to unmask]]
Sent:   Tuesday, February 18, 2003 11:44 AM
To:     [log in to unmask]
Subject:        Re: [TN] CR Technology RTI-6520 AOI machine

We also have this machine. As many of you know, CR Technology was purchased
by Photondynamics a year or two ago. I received a news email from our local
Photondynamics sales rep that effective 1/28/03 Photondynamics was leaving
the AOI field effective immediately.

-Larry Koens-


-----Original Message-----
From: Kathy Kuhlow [mailto:[log in to unmask]]
Sent: Tuesday, February 18, 2003 11:34 AM
To: [log in to unmask]
Subject: Re: [TN] CR Technology RTI-6520 AOI machine


We use this machine.  We have had it inline since 4/02.  We are pretty
happy with it.  We did find that it does really good for shorts but it has
a hard time with opens on fine pitch devices.  We had to really monitor it
and at times we have modified how it inspects parts.  An instance we
noticed is say the part it should find is a 3441 but you put a part that is
close to it like a 3440 and it will accept it.  In these instances we found
that we had the inspection of the part id in one window and because of the
pixel counts it would receive a passing score.  We then changed this to two
windows and then it would reject the part.

It is very easy to program.  It takes the same file setups as our P&P
machines do.  You do need to spend some time with it to get all of the
orientation possibilities but as your library grows this minimizes over
time.

My advice I would give on this machine or any other AOI is to not give up
the inspection process until you are sure the machine is actually
performing.  Take all issues back to the machine.  The program is only as
good as the examples you throw at it.

Don't utilize 0201's so I have no opinion on them.

Kat

---------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700
ext.5315
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700
ext.5315
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------

ATOM RSS1 RSS2