We are in the process of qualifing a 36 pin SMT LCC package for
solderability. The questions are:

1.If we design a test board with 10 LCC units on it, do we daisy chain each
unit individually and tie all 10 units to a common point? or do we daisy
chain all 10 units consecutively?

2. Do we add jumpers or testpoints in various locations around each
individual LCC to help determine where failures may be?

3. If we do tie all 10 units consecutively, do we add jumpers or testpoints
between each set of daisy chained LCC to help determine which unit has
failed?

4. The IPC-9701 spec calls out that a minimum of 50% of the land pad sites
are to require vias, does this mean that out of the 36 pads being used, at
least 18 have to have a via going through them....and does this mean
directly on the pad itself or coming off the pad like what would most likey
be done during standard PWB layouts?

5. The spec also calls out a nominal of 40% copper coverage on odd number
layers, I'm assuming this means even if that layer is not being used...and
the same would go for the even number of layers which is to recieve 70%
nominal.... am I right in assuming this?

The answers mat be straight foward but as a first time designer using this
spec it has me questioning a lot of the requirements. I appreciate your
help in any way.

Best Regards,
Steve Comstantine
[log in to unmask]

---------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------

ATOM RSS1 RSS2