I met strange dimensional stability problem of
standard FR4 double sided 1.0 mm laminate (one of so
called commodity type)at IQC(as received V.S. baking
150 0C for 30 min.)
Is it possible that 1.0 mm laminate D/S over +/-200
PPM? I assume D/S is physical material property which
won't fail.
Anyone has similar experience or the data my engineer
got this time is just so called extreme value in
IPC-TM-650 2.4.39?
Is it necessary to conduct D/S test for 1.0 mm
laminate? Maybe it is not necessary.

Thanks and best regards
Shirley


__________________________________________________
Do you Yahoo!?
Yahoo! Mail Plus - Powerful. Affordable. Sign up now.
http://mailplus.yahoo.com

---------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------

ATOM RSS1 RSS2