        Having been involved with packaging ICs, the caps have silicon that
melts at a certain temperature and seals the cap to the body of the chip. So
after the ICs have been wire bonded to the body( carrier) of the chip, a cap
is placed on each chip carrier before they are run through an oven.  When
they come out the other side, the silicon has cooled enough to solidify and
hermetically seal the cap to the carrier. So a packaging company will be a
good source to obtain caps from.
        Regards,
        Ramon

> -----Original Message-----
> From: Mike Kuczynski [SMTP:[log in to unmask]]
> Sent: Monday, December 09, 2002 9:40 AM
> To:   [log in to unmask]
> Subject:      [TN] Mounting Modified BGA
>
>
> I need some information in mounting a BGA asic, that has been modified.
> The top is cut-off, modifications to the wirebonds to the die are made.
> Then it's sealed w/ this black gunk and covered
> by this yellowish film. The problem is that this black gunk is melting and
> shorting out the whole die, when the BGA is being mounted on the PCB.
>
> Is there a different sealant (black gunk) we should be using to close up
> this BGA? Could it be exceeding the temp. when mounting the BGA? Is there
> another process we should look at?
>
>
>
>  << File: ATT876367.gif >>

---------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------

ATOM RSS1 RSS2