hi,
as you are painfully aware, the problem is that the parylene has gotten between the bga and the pwb (as it should) and bonded the bga to the pwb. no known practical solvents, and you just read that the high temperature required is not an option.
we had airvac design a removal nozzle that had a lever on it and gripped our package by the edges. when the solder at the bga's reflowed, we torqued the package and tore it loose from the parylene.
are you ready for that? didn't think so.
phil
-----Original Message-----
From: WEEKES, MICHAEL HS-SNS [mailto:[log in to unmask]]
Sent: Thursday, December 05, 2002 7:58 AM
To: [log in to unmask]
Subject: [TN] reworking paralyne (paraxylene) coated BGAs and uBGAs
Hello fellow Technetters:
Anyone have any experience removing paralyne (paraxylene) coated BGAs and
uBGAs with conventional air vac DRS 24 type hot air equipment - I tried
conventional reflow profiles and it was very unsuccessful.
[log in to unmask]
---------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------
---------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------
|
|
|