TECHNET Archives

November 2002

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
"Bresnan, Thomas" <[log in to unmask]>
Reply To:
TechNet E-Mail Forum.
Date:
Tue, 5 Nov 2002 09:13:39 -0700
Content-Type:
text/plain
Parts/Attachments:
text/plain (121 lines)
You have to go one step further to IPC-2141, the specification for
Controlled Impedance. In it you will find examples of how to design a coupon
to be able to measure your impedance.
Tom Bresnan
Chairman

IPC High Speed High Frequency Committee

Kulicke & Soffa
K&S Interconnect, Inc.
10365 Sanden Drive
Dallas, TX 75238-2440

214.860.1000
214.860.1012 direct
214.912.1408 mobile
[log in to unmask]
----Original Message-----
From: [log in to unmask] [mailto:[log in to unmask]]
Sent: Tuesday, November 05, 2002 1:07 AM
To: [log in to unmask]
Subject: [TN] COUPON INTEGRATION METHODOLOGY FOR 'CONTROL IMPEDENCE'
Multilayer PCBs


Dear all,

We are a PCB fabricator and manufacture MULTILAYER PCBs which are designed
for 'CONTROL IMPEDENCE'.
We have full info of the controls to be followed wrt LINEWIDTH and
DIELECTRIC THICKNESS during the fabrica-
tion of the CI pcbs as per the data provided by the customer/designer of
the circuit based on their end application.
We also have literature info about the range of DIELECTRIC CONSTANT VALUES
for different raw materials
and their variations wrt frequency, thickness, resin content and other
related parameters. The formulae to be
used for theoritical calculations for STRIPLINE/MICRO STRIPLINE
CONFIGURATIONS are also known.

We have gone through the IPC 2221 AND IPC 2222 standards guidelines, but do
not find  CORRECT INFO on
the type and methodolgy of COUPONS with suitable test points to represent
the CIRCUIT REQTS, (for different
designs) for CONTROL IMPEDENCE PCBs  which can be used for measurement
purposes to confirm that the
 desired values have been achieved in the fabricated PCB .

Request useful guidelines on the Approach and Methodology to be followed
for COUPONS INTEGRATION
in Fabrication for confirming the designed Control Impedence Values are
obtainable through measurements
on the coupons using Standard TDR or any other dedicated measurement
set-up.

Regards,
M A Ranganath
GM - Technical &  Quality
Sanmar Micropack Limited
Plot No.16, Jigani Industrial Area,
Bangalore - 562 106. INDIA
Phone: 91 - 80 - 7825223/224/226/389
Fax     : 91 - 80 - 7825225
Email  : [log in to unmask]








         * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *



 The   information  contained  in  this message is  legally  privileged and
 confidential   information  intended  only   for the use of  the addressed
 individual   or  entity   indicated  in this  message (or  responsible for
 delivery   of  the  message to such person).  It must not be read, copied,
 disclosed,  distributed  or  used  by any person other than the addressee.
 Unauthorised  use, disclosure or copying is strictly prohibited and may be
 unlawful.

 Opinions, conclusions  and other information on  this message  that do not
 relate  to  the  official business of  any of the constituent companies of
 the  SANMAR GROUP  shall  be  understood as  neither given nor endorsed by
 the Group.

 If  you   have  received  this  message in error,  you should destroy this
 message and kindly notify the sender by e-mail.

 Thank you.

         * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *

---------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700
ext.5315
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------