It's a long time since I HASL'd but 2 hours between microetch & flux seems
too long, especially if the atmosphere is as bad as some shops I've seen. It
doesn't take long for a micro etched surface to oxidise. Maybe the micro
etch has an anti-tarnish added to it?
255 °C seems hot for the pot. 240 °C is what I remember, but maybe a higher
temperature means it's easier to blow more off and get flatter pads. 

Geoff Layhe 

-----Original Message-----
From: d. terstegge [mailto:[log in to unmask]]
Sent: 31 October 2002 14:32
To: [log in to unmask]
Subject: Re: [TN] HASL process OK or not ?


Hi Mike, 

Yes this was prior to assembly, it's not localised areas of bare copper
but several pads having a dull appearence and a color somewhere between
brown, green, and solder. There's no solder dome, it's very flat.

Daan Terstegge
Unclassified mail


>>> [log in to unmask] 10/31/02 02:23pm >>>
Was there Cu exposed on the bare PWB you inspected, prior to assembly
/
soldering? 

-----Original Message-----
From: d. terstegge [mailto:[log in to unmask]] 
Sent: Thursday, October 31, 2002 6:00 AM
To: [log in to unmask] 
Subject: [TN] HASL process OK or not ?


Hi Technet,

Yesterday I visited one of our bare board manufacturers and had a
close
look at their HASL-process. The reason for the visit was solderability
problems on BGA-pads, which sometimes look thin and dull. Occasionally
copper seems to be visible through the tinlead.
In general I think this is a very professional boardshop, but (being
not an expert) I don't know what to think about their HASL-process. I
hope someone on this great forum is willing to give me some input on
my
findings, in terms of good or bad, or possibilities for improvement:  

Machine: Quicksilver SM, vertical HASL, 250 kg solderpot, no preheat

Time between microetch (drying) and fluxing can be up to two hours

Solder pot temperature set to 255 °C

Leveling is done is such a way that the solder is as flat as possible,
although the design of the airknives causes a big difference betweeen
the two boardsides. With XRF we measured a thickness of only 0.4
microns
on BGA-pads, with about 3 microns on similar pads on the other
boardside.

Water-based flux from an open tank, without any composition control,
but tank is replaced every 24 hours. 
Solder is replaced every 6 months, but except for copper contamination
no composition-check is ever done. 
When copper is above 0.3 % the dross is skimmed off to assure that
copper content stays below 0.35 %.
Throughput of the machine is about 700 panels per day. 

Daan Terstegge
Thales Communications
Unclassified mail
Personal Website: http://www.smtinfo.net 

---------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV
1.8e
To unsubscribe, send a message to [log in to unmask] with following text
in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives 
Please visit IPC web site http://www.ipc.org/html/forum.htm for
additional
information, or contact Keach Sasamori at [log in to unmask] or
847-509-9700
ext.5315
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV
1.8e
To unsubscribe, send a message to [log in to unmask] with following text
in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives 
Please visit IPC web site http://www.ipc.org/html/forum.htm for
additional
information, or contact Keach Sasamori at [log in to unmask] or
847-509-9700 ext.5315
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700
ext.5315
-----------------------------------------------------


Private & Confidential:
This e-mail message is confidential and is intended solely for the person or
organisation to whom it is addressed.  If the message is received by anyone
other than the addressee please return the message to the sender by replying
to it and then delete the message from your computer.

---------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------

ATOM RSS1 RSS2