TECHNET Archives

September 2002

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Graham Naisbitt <[log in to unmask]>
Reply To:
TechNet E-Mail Forum.
Date:
Fri, 27 Sep 2002 16:53:44 +0100
Content-Type:
text/plain
Parts/Attachments:
text/plain (75 lines)
> Hi Technet,
>
> One of our customers is complaining that the upper limit for our
> ionograph test is set at 3.1 micrograms/cm2 instead of the 1.56
> micrograms/cm2 that the IPC/EIA J-STD-001C prescribes is section 8.3.6.
>
> I know there exists a document  (probably an IPC or MIL-spec)
> explaining how the 1.56 limit should be corrected for the exact type of
> machine. For the Alpha Ionograph 500M the conversion factor is 2,
> resulting in the 3.1 micrograms/cm2 limit.
> However I can't remember where exactly this information can be found,
> and I don't even know if it's still valid. Does anyone has a clue for me
> ?
>
> Daan Terstegge
> Unclassified mail
> Personal Website: http://www.smtinfo.net
>
> ------------------------------------------------------------------------------
> ---
> Technet Mail List provided as a free service by IPC using LISTSERV 1.8e
> To unsubscribe, send a message to [log in to unmask] with following text in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt or (re-start) delivery of Technet send e-mail to
> [log in to unmask]: SET Technet NOMAIL or (MAIL)
> To receive ONE mailing per day of all the posts: send e-mail to
> [log in to unmask]: SET Technet Digest
> Search the archives of previous posts at: http://listserv.ipc.org/archives
> Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
> information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700
> ext.5315
> ------------------------------------------------------------------------------
> ---
>
Daan

I have a copy that I shall dig out for you. If anyone else needs a copy let
me know

--
Regards, Graham Naisbitt
[log in to unmask]
Mobile: +44 (0)79 6858 2121

Concoat Limited - Engineering Electronics Reliability

Web: www.concoat.co.uk   AND  www.concoatsystems.com

NOTE: NEW ADDRESS :NOTE

Sales:

Millfield House, Fleet Road
Fleet, Hampshire GU51 3QF UK
Phone: +44 (0)1252 813706
Fax: +44 (0)1252 813709

Manufacturing and Head Office:

Alasan House, Albany Park
Camberley, Surrey GU16 7PH UK
Phone: +44 (0)1276 691100
Fax: +44 (0)1276 691227

---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
---------------------------------------------------------------------------------

ATOM RSS1 RSS2