Hi Technet,

One of our customers is complaining that the upper limit for our
ionograph test is set at 3.1 micrograms/cm2 instead of the 1.56
micrograms/cm2 that the IPC/EIA J-STD-001C prescribes is section 8.3.6.

I know there exists a document  (probably an IPC or MIL-spec)
explaining how the 1.56 limit should be corrected for the exact type of
machine. For the Alpha Ionograph 500M the conversion factor is 2,
resulting in the 3.1 micrograms/cm2 limit.
However I can't remember where exactly this information can be found,
and I don't even know if it's still valid. Does anyone has a clue for me
?

Daan Terstegge
Unclassified mail
Personal Website: http://www.smtinfo.net

---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
---------------------------------------------------------------------------------

ATOM RSS1 RSS2