Hi Poh! The visual appearance of a solder joint is not necessarily an
indicator of a solder joint's reliability. The old "bright and shiny"
criteria should have become extinct but some old habits apparently have a
life of their own. IPC-STD-001B, paragraph 9.2.4 "Solder Connection" is one
reference you can use to demonstrate to your customer that "bright and
shiny" is not a requirement.  Good Luck.

Dave Hillman
Rockwell Collins
[log in to unmask]





pohkh <[log in to unmask]>@ipc.org> on 09/19/2002 08:18:36 AM

Please respond to [log in to unmask]

Sent by:    TechNet <[log in to unmask]>


To:    [log in to unmask]
cc:

Subject:    [TN] Dull Joint on the Gold plated PCB.


Hi Technetters,

Is there anyone able to help me on having a smooth
shining solder joint on gold-plated PCB.

As I understand that the board with gold-plated gives
a relatively dull joint.

However, I have issue convincing my customer that
this symptom is normal.

Poh

---------------------------------------------------------------------------------

Technet Mail List provided as a free service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700
ext.5315
---------------------------------------------------------------------------------

---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
---------------------------------------------------------------------------------

ATOM RSS1 RSS2