Subject: | |
From: | |
Reply To: | TechNet E-Mail Forum. |
Date: | Mon, 22 Jul 2002 13:57:08 EDT |
Content-Type: | text/plain |
Parts/Attachments: |
|
|
H Simon,
Some BGAs come with voids already in the solder balls--you mmay want to check
for this. The problem with this scenario is reduced solder volume.
If your processes create the voids, it is only a problem if a shear test
shows a failure mode through the solder balls with voids rather than near the
interfaces or pads.
Werner Engelmaier
Engelmaier Associates, L.C.
Electronic Packaging, Interconnection and Reliability Consulting
7 Jasmine Run
Ormond Beach, FL 32174 USA
Phone: 386-437-8747, Fax: 386-437-8737
E-mail: [log in to unmask], Website: www.engelmaier.com
---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
---------------------------------------------------------------------------------
|
|
|