Paul,

The following is the DoDs position on 217F:

I received this e-mail and I am glad to see that someone is working a
replacement for Mil Hdbk 217. As you  may know, the DSIC made a decision
several years ago to let Mil Hdbk 217 "die a natural death". This is still
the current OSD position i.e. we will not support any updates/revisions to
Mil Hdbk 217.

George Desiderio, Deputy Director
Systems Engineering
OUSD(AT&L)/Interoperability
Tel: 703/695-2300
Fax: 703/614-9884
Cell: 703/582-7644
eMail: [log in to unmask]

David A. Douthit
Manager
LoCan LLC


Paul Signorelli wrote:

> i have a question about  the new families of MSD components we have recently been seeing.
> There is now a new group of components being rated as Moisture Sensitive Devices, that are not IC's.  e.g.: LED's, Capacitors, etc....
>
> Is the MSD level now becoming a Quality Level indicating the Quality or Reliability of the part instead of the vapor transmissiblity of the package to prevent the 'Popcorning' problem ?
> Should i purchase a level 2 (non-IC) part from one mfgr, rather than a level 3 (non-IC) part from another because it has successfully passed the Level 2 MSD qualification tests ?
> Are some (non-IC) manufacturers using the MSD Rating system to hide quality defects or inadequate high temperature construction materials ?
> i would suggest that anyone having component failures of these new MS devices
> perform detailed component failure analysis to see if there is a MS vapor transmission (popcorn) failure or some other high temperature failure mechanism (like reversion, epoxy degradation, or CTE problems).
>
> This all could result in a new revision of MIL-HDBK-217 to add  'Pi sub MSD' factors.
>
> Paul Signorelli
> Sanmina-SCI
>
> ---------------------------------------------------------------------------------
> Technet Mail List provided as a free service by IPC using LISTSERV 1.8e
> To unsubscribe, send a message to [log in to unmask] with following text in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
> To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
> Search the archives of previous posts at: http://listserv.ipc.org/archives
> Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
> information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
> ---------------------------------------------------------------------------------

---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
---------------------------------------------------------------------------------

ATOM RSS1 RSS2