Mr. Christian:
Suspect that the fabricator may not be rinsing the parts well after
application of the juice.
They apply hot....if the parts dry between the application and the rinses,
and the rinses are cold....this could spell a problem.
I assume that you are using boards made in Asia?
Rudy Sedlak
RD Chemical Company
---------------------------------------------------------------------------------