Ingemar,

You should see the nervous twitch I've developed!!

David A. Douthit
Manager
LoCan LLC

"Ingemar Hernefjord (EMW)" wrote:

> David,
> these people aren't aware they will never be able to sleep after reading your paper..I presented your reality file for some here, after that they unplugged my copy machine....he-he
> Ingemar
>
> -----Original Message-----
> From: Lusby, Jack R. [mailto:[log in to unmask]]
> Sent: den 24 juni 2002 21:32
> To: [log in to unmask]
> Subject: Re: [TN] Cleaning of Military PWAs That Have Been Soldered
> withNo -CleanFlux
>
> David,
>
> I would also like to get a copy of your paper since we have experience
> issues associated with contamination on mil spec CCA's
>
> Thanks,
> Jack Lusby
> Northrop/Grumman ESSS
> [log in to unmask]
> direct (410)552-2886
> fax     (410)981-5361
>
> > -----Original Message-----
> > From: Debbie Kenney [SMTP:[log in to unmask]]
> > Sent: Monday, June 24, 2002 2:16 PM
> > To:   [log in to unmask]
> > Subject:      Re: [TN] Cleaning of Military PWAs That Have Been Soldered
> > withNo -CleanFlux
> >
> > I would also like to get a copy.
> >
> > Debbie Kenney
> > Engineer
> > M-Flex / AMT
> > Direct  (714) 688-5242
> > Fax     (714) 996-3834
> > [log in to unmask]
> >
> > > -----Original Message-----
> > > From: Gordon F. Davis Jr [SMTP:[log in to unmask]]
> > > Sent: Friday, June 21, 2002 4:30 AM
> > > To:   [log in to unmask]
> > > Subject:      Re: [TN] Cleaning of Military PWAs That Have Been Soldered
> > > withNo-CleanFlux
> > >
> > > May I get an e-copy of the paper you refered to as well.  I also work
> > for
> > > a
> > > military supplier, but we clean everything.  I would like to get further
> > > info on no-clean.
> > >
> > > Gordon Davis
> > > Application Engineer
> > > Rockwell Collins
> > >
> > >
> > >
> > >
> > > David Douthit <[log in to unmask]>@ipc.org> on 06/20/2002 09:10:13 PM
> > >
> > > Please respond to "TechNet E-Mail Forum." <[log in to unmask]>; Please
> > > respond
> > >        to David Douthit <[log in to unmask]>
> > >
> > > Sent by:    TechNet <[log in to unmask]>
> > >
> > >
> > > To:    [log in to unmask]
> > > cc:
> > >
> > > Subject:    Re: [TN] Cleaning of Military PWAs That Have Been Soldered
> > >        withNo-CleanFlux
> > >
> > >
> > > You have landed in a very nasty area. You are correct to be concerned
> > > about
> > > contamination issues.
> > > Even if the residues from the flux do not create migration/leakage
> > current
> > > problems they may
> > > collect other airborne contaminates that can cause problems.
> > >
> > > Process, shipping, and storage control are critical to the reliability
> > of
> > > the circuitry.
> > >
> > > If you wish I have a paper I presented in May of 2001 titled
> > > "Avionics Systems, Reliability, and Harsh Environments"
> > > that I could e-mail you. The information in the paper will
> > > give you a good idea of what type of airborne contamination
> > > issues you may have to deal with.
> > >
> > > David A. Douthit
> > > Manager
> > > LoCan LLC
> > >
> > > Bogert wrote: 6/20/2002 Folks is anyone manufacturing military PWAs
> > using
> > > no-clean flux and not cleaning the PWAs prior to shipment?  If so, what
> > is
> > > your reliability experience with this process? We are considering a
> > > military application (Class 2) where mixed technology (SMT and PTH) PWAs
> > > will be soldered using no-clean flux and then not conformal coated
> > > (assuming the uncoated PWAs can pass our temperature/humidity
> > > qualification
> > > testing).  Although the no-clean flux we will use should be benign (we
> > are
> > > having SIR testing performed to confirm this and Omegameter testing), I
> > am
> > > concerned that contamination may be introduced by other shop processes
> > > such
> > > as mechanical assembly, testing, etc., even if one uses gloves or
> > fingere
> > > cots during handling.  One could argue that after shipment, since the
> > PWAs
> > > are not conformal coated, you can introduce contamination in the field
> > and
> > > therefore, why not not clean prior to shipment. We may be performing
> > board
> > > testing (boundry scan, bed-of-nails, etc) on PWAs that have been
> > soldered
> > > using no-clean flux.  I understand that certain noclean flux can impede
> > > this testing, and also, may cause problems in event we need to conformal
> > > coat the PWAs. Any comments on this subject will be appreciated.
> > >
> > >
> > >
> > >
> > --------------------------------------------------------------------------
> > > -------
> > > Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
> > > To unsubscribe, send a message to [log in to unmask] with following text
> > in
> > > the BODY (NOT the subject field): SIGNOFF Technet
> > > To temporarily halt delivery of Technet send e-mail to [log in to unmask]:
> > > SET Technet NOMAIL
> > > To receive ONE mailing per day of all the posts: send e-mail to
> > > [log in to unmask]: SET Technet Digest
> > > Search the archives of previous posts at:
> > http://listserv.ipc.org/archives
> > > Please visit IPC web site http://www.ipc.org/html/forum.htm for
> > additional
> > > information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700
> > > ext.5315
> > >
> > --------------------------------------------------------------------------
> > > -------
> >
> > --------------------------------------------------------------------------
> > -------
> > Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
> > To unsubscribe, send a message to [log in to unmask] with following text in
> > the BODY (NOT the subject field): SIGNOFF Technet
> > To temporarily halt delivery of Technet send e-mail to [log in to unmask]:
> > SET Technet NOMAIL
> > To receive ONE mailing per day of all the posts: send e-mail to
> > [log in to unmask]: SET Technet Digest
> > Search the archives of previous posts at: http://listserv.ipc.org/archives
> > Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
> > information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700
> > ext.5315
> > --------------------------------------------------------------------------
> > -------
>
> ---------------------------------------------------------------------------------
> Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
> To unsubscribe, send a message to [log in to unmask] with following text in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL
> To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
> Search the archives of previous posts at: http://listserv.ipc.org/archives
> Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
> information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
> ---------------------------------------------------------------------------------
>
> ---------------------------------------------------------------------------------
> Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
> To unsubscribe, send a message to [log in to unmask] with following text in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL
> To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
> Search the archives of previous posts at: http://listserv.ipc.org/archives
> Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
> information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
> ---------------------------------------------------------------------------------

---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
---------------------------------------------------------------------------------

ATOM RSS1 RSS2