Do you  mean "the truth really bites"?  No wonder many choose to "know" it.
Hats off, Dave!
Best regards,
                                            jk

>-----Original Message-----
>From: TechNet [mailto:[log in to unmask]]On Behalf Of Ingemar Hernefjord
>(EMW)
>Sent: Tuesday, June 25, 2002 3:02 AM
>To: [log in to unmask]
>Subject: Re: [TN] Cleaning of Military PWAs That Have Been Soldered
>withNo -CleanFlux
>
>
>David,
>these people aren't aware they will never be able to sleep after
>reading your paper..I presented your reality file for some here,
>after that they unplugged my copy machine....he-he
>Ingemar
>
>-----Original Message-----
>From: Lusby, Jack R. [mailto:[log in to unmask]]
>Sent: den 24 juni 2002 21:32
>To: [log in to unmask]
>Subject: Re: [TN] Cleaning of Military PWAs That Have Been Soldered
>withNo -CleanFlux
>
>
>David,
>
>I would also like to get a copy of your paper since we have experience
>issues associated with contamination on mil spec CCA's
>
>Thanks,
>Jack Lusby
>Northrop/Grumman ESSS
>[log in to unmask]
>direct (410)552-2886
>fax     (410)981-5361
>
>> -----Original Message-----
>> From: Debbie Kenney [SMTP:[log in to unmask]]
>> Sent: Monday, June 24, 2002 2:16 PM
>> To:   [log in to unmask]
>> Subject:      Re: [TN] Cleaning of Military PWAs That Have Been Soldered
>> withNo -CleanFlux
>>
>> I would also like to get a copy.
>>
>> Debbie Kenney
>> Engineer
>> M-Flex / AMT
>> Direct  (714) 688-5242
>> Fax     (714) 996-3834
>> [log in to unmask]
>>
>> > -----Original Message-----
>> > From: Gordon F. Davis Jr [SMTP:[log in to unmask]]
>> > Sent: Friday, June 21, 2002 4:30 AM
>> > To:   [log in to unmask]
>> > Subject:      Re: [TN] Cleaning of Military PWAs That Have
>Been Soldered
>> > withNo-CleanFlux
>> >
>> > May I get an e-copy of the paper you refered to as well.  I also work
>> for
>> > a
>> > military supplier, but we clean everything.  I would like to
>get further
>> > info on no-clean.
>> >
>> > Gordon Davis
>> > Application Engineer
>> > Rockwell Collins
>> >
>> >
>> >
>> >
>> > David Douthit <[log in to unmask]>@ipc.org> on 06/20/2002 09:10:13 PM
>> >
>> > Please respond to "TechNet E-Mail Forum." <[log in to unmask]>; Please
>> > respond
>> >        to David Douthit <[log in to unmask]>
>> >
>> > Sent by:    TechNet <[log in to unmask]>
>> >
>> >
>> > To:    [log in to unmask]
>> > cc:
>> >
>> > Subject:    Re: [TN] Cleaning of Military PWAs That Have Been Soldered
>> >        withNo-CleanFlux
>> >
>> >
>> > You have landed in a very nasty area. You are correct to be concerned
>> > about
>> > contamination issues.
>> > Even if the residues from the flux do not create migration/leakage
>> current
>> > problems they may
>> > collect other airborne contaminates that can cause problems.
>> >
>> > Process, shipping, and storage control are critical to the reliability
>> of
>> > the circuitry.
>> >
>> > If you wish I have a paper I presented in May of 2001 titled
>> > "Avionics Systems, Reliability, and Harsh Environments"
>> > that I could e-mail you. The information in the paper will
>> > give you a good idea of what type of airborne contamination
>> > issues you may have to deal with.
>> >
>> > David A. Douthit
>> > Manager
>> > LoCan LLC
>> >
>> > Bogert wrote: 6/20/2002 Folks is anyone manufacturing military PWAs
>> using
>> > no-clean flux and not cleaning the PWAs prior to shipment?  If so, what
>> is
>> > your reliability experience with this process? We are considering a
>> > military application (Class 2) where mixed technology (SMT and
>PTH) PWAs
>> > will be soldered using no-clean flux and then not conformal coated
>> > (assuming the uncoated PWAs can pass our temperature/humidity
>> > qualification
>> > testing).  Although the no-clean flux we will use should be benign (we
>> are
>> > having SIR testing performed to confirm this and Omegameter testing), I
>> am
>> > concerned that contamination may be introduced by other shop processes
>> > such
>> > as mechanical assembly, testing, etc., even if one uses gloves or
>> fingere
>> > cots during handling.  One could argue that after shipment, since the
>> PWAs
>> > are not conformal coated, you can introduce contamination in the field
>> and
>> > therefore, why not not clean prior to shipment. We may be performing
>> board
>> > testing (boundry scan, bed-of-nails, etc) on PWAs that have been
>> soldered
>> > using no-clean flux.  I understand that certain noclean flux can impede
>> > this testing, and also, may cause problems in event we need to
>conformal
>> > coat the PWAs. Any comments on this subject will be appreciated.
>> >
>> >
>> >
>> >
>>
>--------------------------------------------------------------------------
>> > -------
>> > Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
>> > To unsubscribe, send a message to [log in to unmask] with following text
>> in
>> > the BODY (NOT the subject field): SIGNOFF Technet
>> > To temporarily halt delivery of Technet send e-mail to
>[log in to unmask]:
>> > SET Technet NOMAIL
>> > To receive ONE mailing per day of all the posts: send e-mail to
>> > [log in to unmask]: SET Technet Digest
>> > Search the archives of previous posts at:
>> http://listserv.ipc.org/archives
>> > Please visit IPC web site http://www.ipc.org/html/forum.htm for
>> additional
>> > information, or contact Keach Sasamori at [log in to unmask] or
>847-509-9700
>> > ext.5315
>> >
>>
>--------------------------------------------------------------------------
>> > -------
>>
>>
>--------------------------------------------------------------------------
>> -------
>> Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
>> To unsubscribe, send a message to [log in to unmask] with following text in
>> the BODY (NOT the subject field): SIGNOFF Technet
>> To temporarily halt delivery of Technet send e-mail to [log in to unmask]:
>> SET Technet NOMAIL
>> To receive ONE mailing per day of all the posts: send e-mail to
>> [log in to unmask]: SET Technet Digest
>> Search the archives of previous posts at:
http://listserv.ipc.org/archives
> Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
> information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700
> ext.5315
> --------------------------------------------------------------------------
> -------

----------------------------------------------------------------------------
-----
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send e-mail to [log in to unmask]: SET
Technet NOMAIL
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700
ext.5315
----------------------------------------------------------------------------
-----

----------------------------------------------------------------------------
-----
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send e-mail to [log in to unmask]: SET
Technet NOMAIL
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700
ext.5315
----------------------------------------------------------------------------
-----

---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
---------------------------------------------------------------------------------

ATOM RSS1 RSS2