I would also like to get a copy.

Debbie Kenney
Engineer
M-Flex / AMT
Direct  (714) 688-5242
Fax     (714) 996-3834
[log in to unmask]

> -----Original Message-----
> From: Gordon F. Davis Jr [SMTP:[log in to unmask]]
> Sent: Friday, June 21, 2002 4:30 AM
> To:   [log in to unmask]
> Subject:      Re: [TN] Cleaning of Military PWAs That Have Been Soldered
> withNo-CleanFlux
>
> May I get an e-copy of the paper you refered to as well.  I also work for
> a
> military supplier, but we clean everything.  I would like to get further
> info on no-clean.
>
> Gordon Davis
> Application Engineer
> Rockwell Collins
>
>
>
>
> David Douthit <[log in to unmask]>@ipc.org> on 06/20/2002 09:10:13 PM
>
> Please respond to "TechNet E-Mail Forum." <[log in to unmask]>; Please
> respond
>        to David Douthit <[log in to unmask]>
>
> Sent by:    TechNet <[log in to unmask]>
>
>
> To:    [log in to unmask]
> cc:
>
> Subject:    Re: [TN] Cleaning of Military PWAs That Have Been Soldered
>        withNo-CleanFlux
>
>
> You have landed in a very nasty area. You are correct to be concerned
> about
> contamination issues.
> Even if the residues from the flux do not create migration/leakage current
> problems they may
> collect other airborne contaminates that can cause problems.
>
> Process, shipping, and storage control are critical to the reliability  of
> the circuitry.
>
> If you wish I have a paper I presented in May of 2001 titled
> "Avionics Systems, Reliability, and Harsh Environments"
> that I could e-mail you. The information in the paper will
> give you a good idea of what type of airborne contamination
> issues you may have to deal with.
>
> David A. Douthit
> Manager
> LoCan LLC
>
> Bogert wrote: 6/20/2002 Folks is anyone manufacturing military PWAs using
> no-clean flux and not cleaning the PWAs prior to shipment?  If so, what is
> your reliability experience with this process? We are considering a
> military application (Class 2) where mixed technology (SMT and PTH) PWAs
> will be soldered using no-clean flux and then not conformal coated
> (assuming the uncoated PWAs can pass our temperature/humidity
> qualification
> testing).  Although the no-clean flux we will use should be benign (we are
> having SIR testing performed to confirm this and Omegameter testing), I am
> concerned that contamination may be introduced by other shop processes
> such
> as mechanical assembly, testing, etc., even if one uses gloves or fingere
> cots during handling.  One could argue that after shipment, since the PWAs
> are not conformal coated, you can introduce contamination in the field and
> therefore, why not not clean prior to shipment. We may be performing board
> testing (boundry scan, bed-of-nails, etc) on PWAs that have been soldered
> using no-clean flux.  I understand that certain noclean flux can impede
> this testing, and also, may cause problems in event we need to conformal
> coat the PWAs. Any comments on this subject will be appreciated.
>
>
>
> --------------------------------------------------------------------------
> -------
> Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
> To unsubscribe, send a message to [log in to unmask] with following text in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt delivery of Technet send e-mail to [log in to unmask]:
> SET Technet NOMAIL
> To receive ONE mailing per day of all the posts: send e-mail to
> [log in to unmask]: SET Technet Digest
> Search the archives of previous posts at: http://listserv.ipc.org/archives
> Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
> information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700
> ext.5315
> --------------------------------------------------------------------------
> -------

---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
---------------------------------------------------------------------------------

ATOM RSS1 RSS2