Henry/Werner,

   I work in a Component/Material Analytical Lab.   I conduct cross section
of all interconnection.   I have found interconnection failures in BGA,  the
failure will be:  Fracture in the bulb solder, IMC region or nickel plating.
The problem with subsequence rework is did the PWB reach a reflow temp.
environment which can re-grow the IMC region.  potential for a weak joint.
We can take this off line if so desired.

victor,

-----Original Message-----
From: Werner Engelmaier [mailto:[log in to unmask]]
Sent: Wednesday, June 19, 2002 7:48 AM
To: [log in to unmask]
Subject: Re: [TN] Intermetallic Joint Failure


Hi Henry,
The problem with "rework" is not IMC layers getting too thick, but the
damage
done to the solder joints of neighboring components and the PWB. In all my
years in reliability, I have never seen an "Intermetallic Joint Failure."

Best regards,
Werner Engelmaier

----------------------------------------------------------------------------
-----
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send e-mail to [log in to unmask]: SET
Technet NOMAIL
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700
ext.5315
----------------------------------------------------------------------------
-----

---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
---------------------------------------------------------------------------------

ATOM RSS1 RSS2