In the responses to Steve's question on vacuum sealing, there were two
responses that have me wondering. Both posters said not to use desiccant in
combination with vacuum (though for different reasons.)  Most every bag we
get here direct from the device manufacturer or from distributors has the
bag sucked down tight, and with desiccant. Are the vendors doing something
truly wrong? Are there any device manufacturers out there that can clarify
this?

Thanks.

Regards,
Bob

=======================
Robert Barr
Manufacturing Engineering
Formation, Inc.
Voice: 856-234-5020 x3035
Fax: 856-234-6679

---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
---------------------------------------------------------------------------------

ATOM RSS1 RSS2