TECHNET Archives

May 2002

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Jeff Seeger <[log in to unmask]>
Reply To:
Date:
Thu, 23 May 2002 13:00:09 -0400
Content-Type:
text/plain
Parts/Attachments:
text/plain (46 lines)
> Denis Lefebvre wrote:
>
> snip <
> I have a case now where an EE is asking for a copper fill on BGA
> ground pins. Since this is not easy to describe in a way that every
> one can understand, I am including a small JPG to illustrate. It is a
> 356 pin BGA, 1mm pitch, 0.5mm solder lands.

        Since attachments don't get distributed, let me try to
        make a guess that your EE wants a "puddle" of ground in
        an area of the array, not the whole part.
>
> I am convinced that this will not fare well when they try to solder
> this part, yet the engineer insists on doing it this way. What
> argument can I make, with supporting data, to persuade him?

        If my assumptions are close to correct, what you wind up
        with is part of the array with copper defined lands and
        part of the array with soldermask defined lands.  This
        will probably lead a manufacturer to need to make a sten-
        cil with two different size openings, after they discover
        they have a problem.

        You may be able to anticipate by reducing the soldermask
        pad size to match the copper pad size on affected balls,
        or if your CAD package won't allow this then show the EE
        the % difference in land area.

        HTH,
--

      Jeff Seeger                         Applied CAD Knowledge Inc
      Chief Technical Officer                  Tyngsboro, MA  01879
      jseeger "at" appliedcad "dot" com                978 649 9800

---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
---------------------------------------------------------------------------------

ATOM RSS1 RSS2