Michael,

Dr. Johnson also identified a rotary brush prep process of reworked
underfilled BGA/CSP sites that also improved the Mech Shock survivability
even more.  Probably due to roughing up of the solder mask which improved
underfill adhesion.

Bruce Misner
> ----------
> From:         WEEKES, MICHAEL HS-SNS[SMTP:[log in to unmask]]
> Reply To:     TechNet E-Mail Forum.;WEEKES, MICHAEL HS-SNS
> Sent:         Wednesday, May 15, 2002 10:35 AM
> To:   [log in to unmask]
> Subject:      Re: [TN] BGA's on ruggedized assemblies...
>
> Is underfill really reworkable - I know rework may be feasible, but let's
> be
> honest about the detrimental effects of the thermal effect and
> contamination
> of a site where underfill was applied, cured, heated and
> mechanically/chemically removed.  I welcome comment - our assemblies are
> too
> expensive to scrap out.  Any personal experience with any loctite or other
> "reworkable" undefilled - I rank "reworkable" up there with "washable, but
> not soluble".
>
> -----Original Message-----
> From: [log in to unmask] [mailto:[log in to unmask]]
> Sent: Tuesday, May 14, 2002 8:01 PM
> To: [log in to unmask]
> Subject: Re: [TN] BGA's on ruggedized assemblies...
>
>
> Our Rockwell friends, through the fumes of Mountain Dew and Coke, will say
> "No" if your attachment processes are good enough. Personally, though,
> after some early (low level) vibration failures with some third party
> designed and assembled boards, I built some more to my own spec and
> introduced underfilling as an insurance policy. I hope to be able to
> vibration qual test boards with and without underfilling to see if this
> process is really necessary.
>
> To answer your question, it depends .... on your processes, the operating
> conditions and expected life of the product, and maybe even the board and
> BGA materials. Underfill manufacturers claim that using underfill can
> improve the fatigue life of BGA solder joints by a factor between 3 and 5,
> but it is another process and it involves heating boards an extra time (if
> you use the capillary action type underfill) to carry out the underfill
> process and cure the material. The no-flow type is applied and cured
> concurrently with the assembly of the BGA onto the board and doesn't
> involve the extra thermal excursion.
>
> I recommend you try qualifying boards with underfill and without it to see
> if you need the extra process. Underfilling is not necessary in all
> situations, nor a recommendation, but it won't do any harm either if you
> want to use it anyway.
>
> Peter
>
>
>
> [log in to unmask]   15/05/2002 05:08 AM
> Sent by: TechNet <[log in to unmask]>
>
> Please respond to "TechNet E-Mail Forum."; Please respond to SteveZeva
>
>              To: [log in to unmask]
>              cc: (bcc: DUNCAN Peter/Asst Prin Engr/ST Aero/ST Group)
>              Subject: [TN] BGA's on ruggedized assemblies...
>
>
>
>
>
>
>
>
> Hi All!
>
> Gotta question, when BGA's are used on ruggedized assemblies (at least
> Level-4, probably Level-5), is underfilling BGA's recommended, or a
> necessity?
>
> Thanks, as always...
>
> -Steve Gregory-
>
>
>
> [This e-mail is confidential and may also be privileged. If you are not
> the
> intended recipient, please delete it and notify us immediately; you should
> not copy or use it for any purpose, nor disclose its contents to any other
> person. Thank you.]
>
> --------------------------------------------------------------------------
> --
> -----
> Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
> To unsubscribe, send a message to [log in to unmask] with following text in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt delivery of Technet send e-mail to [log in to unmask]:
> SET
> Technet NOMAIL
> To receive ONE mailing per day of all the posts: send e-mail to
> [log in to unmask]: SET Technet Digest
> Search the archives of previous posts at: http://listserv.ipc.org/archives
> Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
> information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700
> ext.5315
> --------------------------------------------------------------------------
> --
> -----
>
> --------------------------------------------------------------------------
> -------
> Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
> To unsubscribe, send a message to [log in to unmask] with following text in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt delivery of Technet send e-mail to [log in to unmask]:
> SET Technet NOMAIL
> To receive ONE mailing per day of all the posts: send e-mail to
> [log in to unmask]: SET Technet Digest
> Search the archives of previous posts at: http://listserv.ipc.org/archives
> Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
> information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700
> ext.5315
> --------------------------------------------------------------------------
> -------
>

---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest