Hi Steve,
>I would much rather accept 50% hole fill any day than to perform touch-up --
oh the joint looks better >now, but seriously let's look at what damage has
been done to innerlayer interconnections (oh, we can't
>see that so it must be okay).
Very well said. I do not know of any case where 50% hole fill has caused
product failure under any use condition--just consider the redundancy present.
Werner Engelmaier
Engelmaier Associates, L.C.
Electronic Packaging, Interconnection and Reliability Consulting
7 Jasmine Run
Ormond Beach, FL 32174 USA
Phone: 386-437-8747, Fax: 386-437-8737
E-mail: [log in to unmask], Website: www.engelmaier.com
---------------------------------------------------------------------------------