Good Morning Carl,
For starters I would like to say, "Good question, this is going to spread
hysteria throughout Technet land!"  This reminds me of the good 'ol days
providing clarifications and interpretations of mil specs/std that was
somewhat entertaining.
IMHO -- you are correct in your interpretation that the noted exception on
page 6-7 applices to class 2 & 3 (also note that this page conflicts with
table 6-2 Class 2 that states that 75% hole fill is required while 6-7
states 50% is acceptable).  BUT, the user must ensure that this is
acceptable for the intended use environment and all the 'ilities are
unaffected.  I would much rather accept 50% hole fill any day than to
perform touch-up -- oh the joint looks better now, but seriously let's look
at what damage has been done to innerlayer interconnections (oh, we can't
see that so it must be okay).
Have a nice day!

Steve Sauer
Northrop Grumman, Xetron

-----Original Message-----
From: [log in to unmask] [mailto:[log in to unmask]]
Sent: Thursday, May 09, 2002 2:44 PM
To: [log in to unmask]
Subject: [TN] PTH Vertical Fill Requirement IPC610 Rev. C


                Hello,

Looking for the groups opinion(s) on the vertical fill requirement stated on
page 6-7 of IPC-A-610C.

Is the exception pertaining to the Defect Class 3?

---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
---------------------------------------------------------------------------------

ATOM RSS1 RSS2