Brian Ellis <[log in to unmask]>
Reply To:
TechNet E-Mail Forum.
Date:
Tue, 2 Apr 2002 12:00:01 +0300
Content-Type:
text/plain
Parts/Attachments:
text/plain (44 lines)
Phil

Without knowing, I'd make a reasonable guess:
1. they can leak, and
2. by definition, the electrolyte is corrosive to aluminium
Need more be said?

Brian


DUTTON Phil wrote:
>
> Hello Technetters,
>
> Mil-STD-5400 para 4.3.8.2 says that aluminium electrolytic capacitors shall
> not be used in airborne electronic equipment.
> Can anyone please explain why this is so?
>
> thanks,
>
> Phil.
>
> ---------------------------------------------------------------------------------
> Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
> To unsubscribe, send a message to [log in to unmask] with following text in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL
> To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
> Search previous postings at: www.ipc.org > On-Line Resources & Databases > E-mail Archives
> Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
> information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
> ---------------------------------------------------------------------------------

---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search previous postings at: www.ipc.org > On-Line Resources & Databases > E-mail Archives
Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
---------------------------------------------------------------------------------

ATOM RSS1 RSS2