TECHNET Archives

April 2002

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
"Mcmaster, Michael" <[log in to unmask]>
Reply To:
TechNet E-Mail Forum.
Date:
Fri, 26 Apr 2002 08:58:11 -0700
Content-Type:
text/plain
Parts/Attachments:
text/plain (73 lines)
John

The DuPont CB-100 will increase the amount of heat that can be conducted
through the barrel.  My experience with it that most people overestimate
what it can do.  I've done calculations that show for a 0.020" drilled hole
with 0.001" copper barrel, adding CB-100 only increases the amount of heat
by less than 5%. The reason is the CB-100 has a thermal conductivity of 5.23
W/mK vs 395 W/mK for copper.  Even though CB-100 makes up the majority of
the cross sectional area, it only adds a little to the "thermal" cross
section.

I always recommend that potential users of this technology run the numbers
themselves and balance the potential cost increase with the improved
performance.

> ----------
> From:         John Foster[SMTP:[log in to unmask]]
> Reply To:     TechNet E-Mail Forum.;John Foster
> Sent:         Tuesday, April 23, 2002 12:06 PM
> To:   [log in to unmask]
> Subject:      [TN] Via Plug
>
> Hello, I am new to this listserver. I must say that it is very
> informative. I wish I had known of it long ago.
>
> I have a question about via plugging.  Right now
> our board vendor is doing our via plugs with
> I guess with a standard epoxy. We are trying
> to find a solution that would give us a much
> better thermal performance.
>
> We are looking at silver epoxy and this
> material from Dupont.  Does anyone know of
> some material that would give us a really good
> thermal performance. We are in a commercial
> environment. So the material does not have to
> meet industrial specs.
>
> Any input on this matter would be greatly '
> appreciated.
>
> Thank You
>
> John Foster
>
> --------------------------------------------------------------------------
> -------
> Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
> To unsubscribe, send a message to [log in to unmask] with following text in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt delivery of Technet send e-mail to [log in to unmask]:
> SET Technet NOMAIL
> To receive ONE mailing per day of all the posts: send e-mail to
> [log in to unmask]: SET Technet Digest
> Search the archives of previous posts at: http://listserv.ipc.org/archives
> Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
> information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700
> ext.5315
> --------------------------------------------------------------------------
> -------
>

---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
---------------------------------------------------------------------------------

ATOM RSS1 RSS2