Chris,
This has a bit unclear through the years. When working in a
manufacturing facility, I noticed most specified a finished
thickness. Unknown to them, that wasn't what most finished at.
I address that in my book.
Many don't know or realize how the hole plating rules the external
plating. As you stated in a later email, plating is normally 1oz (.0014")
Therefore, you will never have a 2oz external either 1.5oz (.0021")
or 2oz, and up from there. There are some manufacturers that have
many different foil thicknesses, but using that limits the designer/board
to a smaller amount of manufacturers.
I now specify external and plating, so when external values become
critical, they are easily changed.
Also...I have found some manufacturers are plating smaller values and
using odd foil thickness. It takes a lot of guess work out, with
specifying this and is fairly simple.

Chris Robertson
[log in to unmask] <mailto:[log in to unmask]>

Author "PCB Designer's Reference"
to be released in Summer 2002






Greetings Guru's-
I've got a double-sided board. Some traces on the board run 15A
continuous.
Due to space constraints, I have to size the traces for 2oz. copper.

Historically, on the drawing notes I've specified 2oz FINISHED copper
weight and not called out a starting weight (also specified
.001" min/avg.
plating in holes). My thoughts were that I didn't care what the
base copper
was as long as the end product met the callouts. Our good-old supplier
started with 1oz. and plated up to 2oz.

We are re-vamping all our standard notes to try to better
reference IPC and
other specs. Global market, more outsourcing, all that. It
seems I should
specify a starting copper thickness on the drawing, as well as
a finished
copper thickness.

I'm reading IPC-6012 (page 14, table 3-9) and trying to
understand why 2oz.
copper AFTER plating has a min. thickness of 76uM (.003"). Seems like it
ought to be .0038' (0.097uM). Is that because it's a MIN instead of an
average?

What do/would you put on the fab notes for starting and
finished Cu thk.?
Quick responses would be appreciated.

Thanks,
-Chris



"This e-mail message is intended only for the use of the named
recipient(s).
The information contained therein may be confidential or privileged, and
its
disclosure or reproduction is strictly prohibited. If you are
not the named
recipient, please return it immediately to its sender at the
above address
and destroy it."

----------------------------------------------------------------
-----------------
DesignerCouncil Mail List provided as a free service by IPC
using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with
following text in
the BODY (NOT the subject field): SIGNOFF DesignerCouncil.
To set a vacation stop for delivery of DesignerCouncil send:
SET DesignerCouncil NOMAIL
Search previous postings at: www.ipc.org > On-Line Resources &
Databases > E-mail Archives
Please visit IPC web site http://www.ipc.org/html/forum.htm for
additional
information, or contact Keach Sasamori at [log in to unmask] or
847-509-9700 ext.5315
----------------------------------------------------------------
-----------------

---------------------------------------------------------------------------------
DesignerCouncil Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF DesignerCouncil.
To set a vacation stop for delivery of DesignerCouncil send: SET DesignerCouncil NOMAIL
Search previous postings at: www.ipc.org > On-Line Resources & Databases > E-mail Archives
Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
---------------------------------------------------------------------------------

ATOM RSS1 RSS2