Hi Peter! You have me confused (which is a normal state for me if I don't
have a Coke in my hand). Collins has been using BGAs in avionics use
environments, not underfilled, with acrylic conformal coating very
successfully for a couple of years. What was the reason/rationale for using
BGAs with underfill? Was is an issue with solder joint thermal cycle
fatigue for a given use environment? Corrosion? Customer requirements?
Residual flux issues? Sheer terror of the unknown?

Dave Hillman
Rockwell Collins
[log in to unmask]




[log in to unmask]@ipc.org> on 03/26/2002 07:48:52 PM

Please respond to "TechNet E-Mail Forum." <[log in to unmask]>; Please respond
       to [log in to unmask]

Sent by:    TechNet <[log in to unmask]>


To:    [log in to unmask]
cc:

Subject:    Re: [TN] Conformal Coating BGA's


Hi, Bruce,

We apply Humiseal acrylic coating to boards that fit your description and
application precisely, except that we do underfill the BGA's with a
reworkable epoxy, applied after assembly. The only exception was for the
case of two boards destined for temperature cycling measurement, for which
we couldn't get a supply of underfill material at the time. We substituted
thinned Humiseal as the boards would not be flying, as we were concerned
about entrapped air and also no suuport for the BGA joints. Humiseal is not
a proper substitute for the specialised proper epoxy, but was sufficient
for our particular purpose.

The main issue as I see it would be moisture and other contaminants in the
entrapped air, but I have no first hand data to help you decide if that
causes problems or not.

Good luck

Peter




                    "Misner,
                    Bruce"               To:     [log in to unmask]
                    <Bruce_Misner        cc:     (bcc: DUNCAN Peter/Asst
                    Prin Engr/ST
                    @ATK.COM>            Aero/ST Group)
                    Sent by:             Subject:     [TN] Conformal
                    Coating BGA's
                    TechNet
                    <[log in to unmask]
                    ORG>


                    03/20/02
                    03:48 AM
                    Please
                    respond to
                    "TechNet
                    E-Mail
                    Forum.";
                    Please
                    respond to
                    "Misner,
                    Bruce"






My question of the day: Is anyone conformal coating (not parylene) plastic
BGA's on FR-4 in Hi-Rel applications (aircraft; -20 to +71C ambient
operating temperature requirement) without benefit of an underfil?  If yes,
has entrapped air been a major issue?  Anyone care to comment on this
approach?

Regards,
Bruce Misner

---------------------------------------------------------------------------------


Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send e-mail to [log in to unmask]:
SET Technet NOMAIL
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search previous postings at: www.ipc.org > On-Line Resources & Databases >
E-mail Archives
Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700
ext.5315
---------------------------------------------------------------------------------






[This e-mail is confidential and may also be privileged. If you are not the
intended recipient, please delete it and notify us immediately; you should
not copy or use it for any purpose, nor disclose its contents to any other
person. Thank you.]

---------------------------------------------------------------------------------

Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send e-mail to [log in to unmask]:
SET Technet NOMAIL
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search previous postings at: www.ipc.org > On-Line Resources & Databases >
E-mail Archives
Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700
ext.5315
---------------------------------------------------------------------------------

---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search previous postings at: www.ipc.org > On-Line Resources & Databases > E-mail Archives
Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
---------------------------------------------------------------------------------

ATOM RSS1 RSS2