Peter

It only seems like a "circus"....

> ----------
> From:         [log in to unmask][SMTP:[log in to unmask]]
> Reply To:     TechNet E-Mail Forum.;[log in to unmask]
> Sent:         Wednesday, March 13, 2002 7:42 PM
> To:   [log in to unmask]
> Subject:      Re: [TN] Solder Joint Mechanical Stress
>
> Was this strength test written into the requirements when the job was
> taken
> on? 20 in pounds is quite a torque to apply to an electronic component.
> Does your customer have any first-hand experience of circus board
> manufacture? - it's sounds like "no", or he'ld understand for himself why
> it's a bad idea to perform a test like this. Is it intended to be 100%
> inspection?
>
> The process to stick the heatsinks to the BGA's should have been confirmed
> as part of a product qualification test, as should the means and method of
> testing the adhesion. Properly specified, this process can then be passed
> onto CM's or whoever assembles the boards to repeat.
>
> For process monitoring purposes, to ensure adequate adhesion is being
> maintained, batch sampling can be done, but I wouldn't do it on expensive
> "live" product - I would load the occasional board with appropriate dummy
> components, mount the heatsink and test those. If there's a problem, stop
> and review the processes.
>
> Otherwise, what is the test going to prove? Either the heatsink comes off,
> or the BGA does (especially if it's one of Earl's illigitimate TI things),
> or they both stay on the board but the solder joints (ball to board or
> balls to device or both) have been unnecessarily stressed, which is bound
> to reduce working life by anyone's reasoning - by how much, should have
> been one of the HALT test results, using a non-torqued set of pieces for
> comparison.
>
> How to change the customer's mind? Ask what qual tests were done and what
> results were obtained along the lines I suggested above, and judge for
> yourself if they were adequate. If not explain why you think so, and if
> he's still adamant about carrying out the test on live product, get him to
> sign a disclaimer removing your liability for failures now or later for
> any
> boards on which this test has been carried out.
>
> Can't suggest anything else, but good luck.
>
> Peter
>
>
>
>
>                     Carl Ray
>                     <carlr.ray@SANMIN        To:     [log in to unmask]
>                     A-SCI.COM>               cc:     (bcc: DUNCAN
> Peter/Asst Prin Engr/ST
>                     Sent by: TechNet         Aero/ST Group)
>                     <[log in to unmask]>        Subject:     [TN] Solder
> Joint Mechanical Stress
>
>
>                     03/14/02 12:17 AM
>                     Please respond to
>                     "TechNet E-Mail
>                     Forum."; Please
>                     respond to Carl
>                     Ray
>
>
>
>
>
>
> I have a customer who is requiring that I verify the bond strength of a
> heat sink that is glued to the top of PBGA. The customer has supplied me
> with a torque tool to verify the strength of the bond between the heat
> sink and the BGA. I have concerns that testing the strength of the glue
> bond may affect the solder joint reliability of the BGA. The tool
> supplied by the customer is set at 20 in pound torque. Any ideas how I
> can "change" my customer mind?
>
> --------------------------------------------------------------------------
> -------
>
> Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
> To unsubscribe, send a message to [log in to unmask] with following text in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt delivery of Technet send e-mail to [log in to unmask]:
> SET Technet NOMAIL
> To receive ONE mailing per day of all the posts: send e-mail to
> [log in to unmask]: SET Technet Digest
> Search previous postings at: www.ipc.org > On-Line Resources & Databases >
> E-mail Archives
> Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
> information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700
> ext.5315
> --------------------------------------------------------------------------
> -------
>
>
>
>
>
> [This e-mail is confidential and may also be privileged. If you are not
> the
> intended recipient, please delete it and notify us immediately; you should
> not copy or use it for any purpose, nor disclose its contents to any other
> person. Thank you.]
>
> --------------------------------------------------------------------------
> -------
> Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
> To unsubscribe, send a message to [log in to unmask] with following text in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt delivery of Technet send e-mail to [log in to unmask]:
> SET Technet NOMAIL
> To receive ONE mailing per day of all the posts: send e-mail to
> [log in to unmask]: SET Technet Digest
> Search previous postings at: www.ipc.org > On-Line Resources & Databases >
> E-mail Archives
> Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
> information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700
> ext.5315
> --------------------------------------------------------------------------
> -------
>

---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search previous postings at: www.ipc.org > On-Line Resources & Databases > E-mail Archives
Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
---------------------------------------------------------------------------------

ATOM RSS1 RSS2