TECHNET Archives

March 2002

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Graham Naisbitt <[log in to unmask]>
Reply To:
TechNet E-Mail Forum.
Date:
Wed, 20 Mar 2002 23:09:19 -0000
Content-Type:
text/plain
Parts/Attachments:
text/plain (115 lines)
Dave

Any chance I could have a copy of that please?

Regards Graham Naisbitt

[log in to unmask] <mailto:[log in to unmask]>

Concoat Limited
Alasan House, Albany Park
Camberley GU16 7PH - UK

www.concoat.co.uk <http://www.concoat.co.uk>

Phone: +44 1276 691100
Fax: +44 1276 691227
Mobile: +44 79 6858 2121


> -----Original Message-----
> From: TechNet [mailto:[log in to unmask]]On Behalf Of Dave Hillman
> Sent: 20 March 2002 14:15
> To: [log in to unmask]
> Subject: Re: [TN] Conformal Coating BGA's
>
>
> Hi Bruce! We are routinely putting acrylic conformal coating over plastic
> BGA components without using underfill for avionics use environments. We
> did a fair amount of testing looking both at paraylene and acrylic prior
> implementation. This work was published at the IPC APEX 2000 Conference in
> Long Beach (the paper title was "An Investigation of the Effects
> of Printed
> Wiring Board Surface Finish and Conformal Coating for Ball Grid Array
> Assembly"). Can you expand on your concern of "entrapped air"? We have not
> seen any issues for that topic after 2 years of production experience.
>
> Dave Hillman
> Rockwell Collins
> [log in to unmask]
>
>
>
>
> "Misner, Bruce" <[log in to unmask]>@ipc.org> on 03/19/2002 01:48:38 PM
>
> Please respond to "TechNet E-Mail Forum." <[log in to unmask]>;
> Please respond
>        to "Misner, Bruce" <[log in to unmask]>
>
> Sent by:    TechNet <[log in to unmask]>
>
>
> To:    [log in to unmask]
> cc:
>
> Subject:    [TN] Conformal Coating BGA's
>
>
> My question of the day: Is anyone conformal coating (not parylene) plastic
> BGA's on FR-4 in Hi-Rel applications (aircraft; -20 to +71C ambient
> operating temperature requirement) without benefit of an
> underfil?  If yes,
> has entrapped air been a major issue?  Anyone care to comment on this
> approach?
>
> Regards,
> Bruce Misner
>
> ------------------------------------------------------------------
> ---------------
>
> Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
> To unsubscribe, send a message to [log in to unmask] with following text in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt delivery of Technet send e-mail to [log in to unmask]:
> SET Technet NOMAIL
> To receive ONE mailing per day of all the posts: send e-mail to
> [log in to unmask]: SET Technet Digest
> Search previous postings at: www.ipc.org > On-Line Resources & Databases >
> E-mail Archives
> Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
> information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700
> ext.5315
> ------------------------------------------------------------------
> ---------------
>
> ------------------------------------------------------------------
> ---------------
> Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
> To unsubscribe, send a message to [log in to unmask] with following text in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt delivery of Technet send e-mail to
> [log in to unmask]: SET Technet NOMAIL
> To receive ONE mailing per day of all the posts: send e-mail to
> [log in to unmask]: SET Technet Digest
> Search previous postings at: www.ipc.org > On-Line Resources &
> Databases > E-mail Archives
> Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
> information, or contact Keach Sasamori at [log in to unmask] or
> 847-509-9700 ext.5315
> ------------------------------------------------------------------
> ---------------
>

---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search previous postings at: www.ipc.org > On-Line Resources & Databases > E-mail Archives
Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
---------------------------------------------------------------------------------

ATOM RSS1 RSS2